What was the aim of this review?
The aim of this Cochrane Review was to find out if new ways of doing laser treatment for proliferative diabetic retinopathy (explained under 'What was studied in the review?' below) work better than standard treatment. Cochrane researchers collected and analysed all relevant studies to answer this question and found 11 studies.
Key messages
There is limited evidence on the benefits and harms of different laser systems or strategies compared with the standard treatment.
What was studied in the review?
People with diabetes can have problems in the back of their eyes that may affect their sight. One of these problems is the growth of harmful new blood vessels in the retina (the layer that covers the back of the eye that allows people to see); this is called proliferative diabetic retinopathy, referred to as ‘PDR’. Sight loss can occur as a result of PDR. Argon laser has been used to treat PDR for many years. New types of laser and new ways of doing laser treatment have been developed to treat PDR. The aim of this review was to assess the evidence for the benefits and harms of these new treatments.
What are the main results of the review?
The Cochrane researchers found 11 relevant studies. Four studies were done in Italy, two studies were done in the US, one in South Korea, one in Iran, one in Slovenia, one in Greece and one in India. All the people included in these studies had PDR due to type 1 or type 2 diabetes. Most of these studies were small and provide limited evidence on which to base treatment decisions.
How up to date is this review?
Cochrane researchers searched for studies that had been published up to 8 June 2017.
Modern laser techniques and modalities have been developed to treat PDR. However there is limited evidence available with respect to the efficacy and safety of alternative laser systems or strategies compared with the standard argon laser as described in ETDRS
Diabetic retinopathy (DR) is a chronic progressive disease of the retinal microvasculature associated with prolonged hyperglycaemia. Proliferative DR (PDR) is a sight-threatening complication of DR and is characterised by the development of abnormal new vessels in the retina, optic nerve head or anterior segment of the eye. Argon laser photocoagulation has been the gold standard for the treatment of PDR for many years, using regimens evaluated by the Early Treatment of Diabetic Retinopathy Study (ETDRS). Over the years, there have been modifications of the technique and introduction of new laser technologies.
To assess the effects of different types of laser, other than argon laser, and different laser protocols, other than those established by the ETDRS, for the treatment of PDR. We compared different wavelengths; power and pulse duration; pattern, number and location of burns versus standard argon laser undertaken as specified by the ETDRS.
We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2017, Issue 5); Ovid MEDLINE; Ovid Embase; LILACS; the ISRCTN registry; ClinicalTrials.gov and the ICTRP. The date of the search was 8 June 2017.
We included randomised controlled trials (RCTs) of pan-retinal photocoagulation (PRP) using standard argon laser for treatment of PDR compared with any other laser modality. We excluded studies of lasers that are not in common use, such as the xenon arc, ruby or Krypton laser.
We followed Cochrane guidelines and graded the certainty of evidence using the GRADE approach.
We identified 11 studies from Europe (6), the USA (2), the Middle East (1) and Asia (2). Five studies compared different types of laser to argon: Nd:YAG (2 studies) or diode (3 studies). Other studies compared modifications to the standard argon laser PRP technique. The studies were poorly reported and we judged all to be at high risk of bias in at least one domain. The sample size varied from 20 to 270 eyes but the majority included 50 participants or fewer.
Nd:YAG versus argon laser (2 studies): very low-certainty evidence on vision loss, vision gain, progression and regression of PDR, pain during laser treatment and adverse effects.
Diode versus argon laser (3 studies): very-low certainty evidence on vision loss, vision gain, progression and regression of PDR and adverse effects; moderate-certainty evidence that diode laser was more painful (risk ratio (RR) troublesome pain during laser treatment (RR 3.12, 95% CI 2.16 to 4.51; eyes = 202; studies = 3; I2 = 0%).
0.5 second versus 0.1 second exposure (1 study): low-certainty evidence of lower chance of vision loss with 0.5 second compared with 0.1 second exposure but estimates were imprecise and compatible with no difference or an increased chance of vision loss (RR 0.42, 95% CI 0.08 to 2.04, 44 eyes, 1 RCT); low-certainty evidence that people treated with 0.5 second exposure were more likely to gain vision (RR 2.22, 95% CI 0.68 to 7.28, 44 eyes, 1 RCT) but again the estimates were imprecise . People given 0.5 second exposure were more likely to have regression of PDR compared with 0.1 second laser PRP again with imprecise estimate (RR 1.17, 95% CI 0.92 to 1.48, 32 eyes, 1 RCT). There was very low-certainty evidence on progression of PDR and adverse effects.
'Light intensity' PRP versus classic PRP (1 study): vision loss or gain was not reported but the mean difference in logMAR acuity at 1 year was −0.09 logMAR (95% CI −0.22 to 0.04, 65 eyes, 1 RCT); and low-certainty evidence that fewer patients had pain during light PRP compared with classic PRP with an imprecise estimate compatible with increased or decreased pain (RR 0.23, 95% CI 0.03 to 1.93, 65 eyes, 1 RCT).
'Mild scatter' (laser pattern limited to 400 to 600 laser burns in one sitting) PRP versus standard 'full' scatter PRP (1 study): very low-certainty evidence on vision and visual field loss. No information on adverse effects.
'Central' (a more central PRP in addition to mid-peripheral PRP) versus 'peripheral' standard PRP (1 study): low-certainty evidence that people treated with central PRP were more likely to lose 15 or more letters of BCVA compared with peripheral laser PRP (RR 3.00, 95% CI 0.67 to 13.46, 50 eyes, 1 RCT); and less likely to gain 15 or more letters (RR 0.25, 95% CI 0.03 to 2.08) with imprecise estimates compatible with increased or decreased risk.
'Centre sparing' PRP (argon laser distribution limited to 3 disc diameters from the upper temporal and lower margin of the fovea) versus standard 'full scatter' PRP (1 study): low-certainty evidence that people treated with 'centre sparing' PRP were less likely to lose 15 or more ETDRS letters of BCVA compared with 'full scatter' PRP (RR 0.67, 95% CI 0.30 to 1.50, 53 eyes). Low-certainty evidence of similar risk of regression of PDR between groups (RR 0.96, 95% CI 0.73 to 1.27, 53 eyes). Adverse events were not reported.
'Extended targeted' PRP (to include the equator and any capillary non-perfusion areas between the vascular arcades) versus standard PRP (1 study): low-certainty evidence that people in the extended group had similar or slightly reduced chance of loss of 15 or more letters of BCVA compared with the standard PRP group (RR 0.94, 95% CI 0.70 to 1.28, 270 eyes). Low-certainty evidence that people in the extended group had a similar or slightly increased chance of regression of PDR compared with the standard PRP group (RR 1.11, 95% CI 0.95 to 1.31, 270 eyes). Very low-certainty information on adverse effects.